HEWLETT PACKARD CodeMaster XL DEFIBRILLATOR / MONITOR
Product Functionality
-
Technician Notes: USED but in Fair Condition
HEWLETT PACKARD
CodeMaster
DEFIBRILLATOR / MONITOR
MODEL: 1722B XL
OPTIONS: ABA 049 C02 C32 C80
INPUT: 100-230V +/- 15%
120VA NOMINAL
248VA MAXIMUM
BATTERY: 12VDC @ 4AH
DIMENSIONS: 15.75" x 12.75" x 8.0"
40.05cm x 32.39cm x 20.32cm
WEIGHT: 24LBS (10kg) INCLUDES EXTERNAL PADDLES, BATTERY, AND RECORDER PAPER
DEFIBRILLATOR:
OUTPUT ENERGY: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300 AND 360 JOULES
WAVEFORM: DAMPED SINUSOIDAL (LOWN)
CHARGE CONTROL: PUSH-BUTTON ON APEX PADDLE AND ON
FRONT PANEL
CHARGE TIME: LESS THAN 5 SECONDS TO 360 JOULES
ARMED INDICATOR: CHARGE DONE TONE, CHARGE DONE LAMP ON APEX HANDLE, AND AVAILABLE ENERGY INDICATOR ON DISPLAY
PADDLE CONTACT INDICATOR: STANDARD PADDLES ARE ANTERIOR/ANTERIOR, ADULT AND PEDIATRIC
CALIBRATION DATE: MAY 24, 2023 @ 343 CAPACITANCE
EXTERNAL PADDLES CHARGE AND DISCHARGE PROPERLY
BATTERY CHARGE OPERATIONAL
JOULES INDICATOR SWITCH FULLY FUNCTIONAL - Items Included: HEWLETT PACKARD CodeMaster XL DEFIBRILLATOR / MONITOR
-
Missing Components: OPERATION MANUAL
ACCESSORIES
POWER SUPPLY CABLE
-
R2v3 Functionality:
F3 - Key Functions Working
- A subset of the primary functions of the device that an ordinary user of the device expects to function are verified working through manual or software tests
- Software may not be loaded or configured
- Hardware required for key functions to be tested may have been removed after testing (e.g. hard drive)
- May be missing components or parts not essential to key functions
- Secondary functions may not be tested or working
- May not include focus materials that are not working or not tested
- All missing components or parts will be listed for each item
Cosmetic Description
-
Scuffs/Scratches/Marks: some scuffs and scratches
- Other Notes:
-
R2v3 Cosmetics:
C3 - Used Fair
- Cosmetic blemishes are consistent with wear, including multiple dents, discoloration, and light to heavy scratches
- Damage to latches, hinges, keyboards, etc.
- Some parts, panels, bezels, or covers may be missing
Buyer accepts all responsibility for the electrical safety inspection, testing and calibration when applicable, of a purchased item. Medical and dental items must be inspected for safety by a biomedical technician before being placed into use. The buyer is responsible for ensuring the safety of the item for its intended use. If the item is to be used in conjunction with patient care and/or diagnosis, it is the responsibility of the buyer to get proper certifications or licenses for the use of the item."""